Vol.6 , No. 2, Publication Date: Jul. 28, 2020, Page: 9-13
[1] | Eddy Fotso Kamdem, Condensed Matter and Nanoscience Laboratory, Department of Physics, Faculty of Science, University of Dschang, Dschang, Cameroon. |
[2] | Odette Ngano Samba, Condensed Matter and Nanoscience Laboratory, Department of Physics, Faculty of Science, University of Dschang, Dschang, Cameroon; Yaoundé General Hospital, Yaoundé, Cameroon. |
[3] | Serge Abogo, Essos Hospital Center, Yaoundé, Cameroon. |
[4] | Alain Fotue, Condensed Matter and Nanoscience Laboratory, Department of Physics, Faculty of Science, University of Dschang, Dschang, Cameroon. |
This report proposes techniques for optimizing the radiation exposure of pediatric patients to adult CT scanners in developing countries. A prospective method was carried out. Most hospitals in this country have older generations of adult CT scanners without a functioning pediatric (software) protocol. A study was done in 2015 and 2018 on 161 pediatric patients to verify improved practices in the hospitals studied through the proposed strategies. In 2015, the principles of radioprotection were not rigorously respected, but in 2018, the practice improved. The sensitization of medical staff in terms of radioprotection today is visible. Dose parameters decreased in 2015 to 2018 for skull examinations. The activation of the pediatric protocol option in the software used for adult CT scanner in hospitals, the reduction of high tube voltage (kV), the tube current-time product (mAs) and the respect of the immobilization measures proposed in this work according to the ages are factors contributing to the improvement of pediatric examinations in this emerging country. The use of radiological protocols and procedures that are not suitable for pediatric examination delivers great scan lengths resulting in exposure to ionizing radiation of some unnecessary parts in an examination.
Keywords
Pediatric CT Scanner, Optimization of Protocols, Dose of Ionizing Radiation
Reference
[01] | Chang VY, Davidson TB. Childhood exposures and risk of malignancy in adulthood. Pediatr Ann 2015; 44: 270-273. |
[02] | Hall EJ. Radiation biology for pediatricradiologists. PediatrRadiol 2009; 39: 57-64. |
[03] | Tchaou M., Gnakadja GN., N’timon B. and al. Revue Des Doses d’Exposition Et Des Méthodes d’Optimisation En Tomodensitométrie (TDM) De l’Enfant Au Togo. European Scientific Journal edition 2016; 6: 56-66. ISSN: 1857 – 7881 (Print) e - ISSN 1857- 7431. |
[04] | Verdun FR., Gutierrez D., Vader JP. and al. CT radiation dose in children: a survey to establish age-based diagnostic reference levels in Switzerland, Eur Radiol, 2008; 18: 1980-1986. |
[05] | Vasseleva J., Rehani MM., AL-Dhuhli H. and al. IAEA survey of pediatric computed tomography practice in 40 countries in Asia, Europe, Latin America and Africa: procedures and protocols, Computed Tomography. Eur Radiol 2012: 1-9. DOI 10.1007/s00330-012-2639-3. |
[06] | Shrimpton PC., Hillier MC., Lewis MA. and al. Doses from Computed Tomography (CT) Examinations in the UK – 2003 Review, NRPB-W67 2005: 22-31. ISBN 085951 556 7. |
[07] | Brisse H. and Auber B.(2009). CT exposure from pediatric MDCT: results from the 2007-2008 SFIPP/ISRN survey. J Radiol, 90, 2007: 207-215. |
[08] | Galanski M., Nagel HD., Stamm G. and al. Pediatric CT exposure practice in the federal republic of Germany: results of a nationwide survey in 2005–2006, Medizinische Hochs-chule, Hannover, http://www.sascrad.com/attachments/File/Report_German_Paed-CT-Survey _2005 _06.pdf. |
[09] | Décrets, arêtes, circulaires. Textes généraux. Ministère du travail, de l’emploi et de la sante. Arrêté du 24 octobre 2011 relatif aux Niveaux de Référence Diagnostiques en radiologie et en médecine nucléaire. NOR: ETSP1129093A. Texte 22/147. |
[10] | Keith J., Marilyn J., Sue C. and al. Applegate; Image Gently: Ten Steps You Can Take to Optimize Image Quality and Lower CT Dose for Pediatric Patients; Medical Physics and Informatics April 2010; 194 (4). |
[11] | Heliot C, Mestdagh P, Opsomer H, Chaffiotte C (2008), Comment réaliser un bon examen TDM en radiopédiatrie. [En ligne] Service d’imagerie de la femme et de l’enfant. Hôpital Jeanne de Flandre, CHRU LILLE, PP 4-30. (Consulté le 20 Aout 2014). |
[12] | Brenner D-J, Hall E-J. Computed tomography an increasing source of radiation exposure. N Engl J Med 2007. 29 Nov; 357 (22): 2277-84. |
[13] | Siegel M, Schmidt B, Bradley D et al. Radiation Dose and Image Quality in Pediatric CT: Effect of Technical Factors and Phantom Size and Shape », Radiology 2004; 233: 515-522. |
[14] | Gervaise A. Optimisation et réduction de la dose d’irradiation au scanner: aspects techniques et impact en pratique clinique courante. Médecine humaine et pathologie. Université de Lorraine, 2016. Français. |
[15] | Arrêté du 23 mai 2019 portant homologation de la décision n° 2019-DC-0667 de l'Autorité de sûreté nucléaire du 18 avril 2019 relative aux modalités d'évaluation des doses de rayonnements ionisants délivrées aux patients lors d'un acte de radiologie, de pratiques interventionnelles radioguidées ou de médecine nucléaire et à la mise à jour des niveaux de référence diagnostiques associés. NOR: SSAP1915191A. |